Case Study - Varnish Contamination

Operators of a large Hydraulic Shear noticed elevated temperatures

Lube oil Varnish Contamination large Hydraulic Shear

TOPIC: Varnish Contamination

ASSET: Large Hydraulic Shear

DATE: May 24, 2016

 

Problem:

Operators of a large Hydraulic Shear noticed elevated temperatures and a discoloration of the oil in their 10,000 litre hydraulic oil system. This prompted them to conduct oil analysis, and the lab results revealed an elevated varnish potential number of MPC 49. If left untreated, the operators were worried that varnish would eventually cause premature failure of the large Hydraulic Shear, requiring costly repairs and down-time.

 

Solution:

To effectively mitigate the varnish contamination in the hydraulic oil, the plant decided to implement a 40lpm Varnish Removal System utilizing Granular Adsorbent Media and High Efficiency Beta>1000 Filter Elements to re-circulate the reservoir in a kidney-loop configuration, continuously removing impurities as the hydraulics of the Shear were actuated.

 

Results:

The starting varnish content in the oil was MPC 49. After approximately 6 weeks of run-time, the varnish potential dropped significantly to MPC 9.

 

Conclusion:

By implementing a Varnish Removal System from OilQuip, and maintaining the oil of a large Hydraulic Shear at or below the recommended varnish potential of MPC 10, operators at this large Steel Mill did everything possible to ensure optimal reliability and operation/performance of the Hydraulic Shear, while minimizing down-time and costly repairs.

Leave a Reply

Your email address will not be published. Required fields are marked *